MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful

MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful
MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful
MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful

Large Image :  MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful

Product Details:
Place of Origin: China
Brand Name: HiYi
Certification: CE
Model Number: MIC600
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: paper case
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful

Description
Product Name: Toxic And Harmful Gas Detector Type: Fixed Multi Gas Detector
Weight: 1.8(kg) Size: 210*170*85mm (L*H*W)
Gas Unit: PPM, Mg/m3, Vol%, LEL%, PPHM, Ppb, Mg/l. Function: Fixed Multi Gas Detector
Highlight:

mic600 ch4 methane gas detector

,

mic 600 methane gas detector

,

toxic ch4 methane gas detector

MIC600 Online Fixed Composite Type Toxic And Harmful methane Gas Detector

 

OVERVIEW

 

 

 

MIC600 Series gas detector can be used in 24 hours continuous online monitoring of concentrations of multiple types of gases in the filed.The types for detection are more than 500 types.

With a 4-20 mA analogue output, can be simply integrated into a Distributed Control System (DCS) to provide warnings and enable control of high levels in the working environment.

Simple to install service and calibrate, MIC600 requires no hot work permit and the PID sensor is accessible and changeable in a matter of seconds.

Strong, durable and explosion-proof shell and fluorocarbon surface treatment process are suitable for the use at a variety of hazardous places and corrosive environments, it is wear-resistant.

Simple calibration procedure.

Easily integrated into a control system.

MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful 0

FEATURES & BENEFITS

 

 

MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful 1

 

Fast and Efficient Gas Detection Function

  • It can be used in 24 hours continuous online monitoring of multi field gas concentration ,up to 6 gases and the types for detection are more than 500 types.
  • There are 7 gas units to display, and the units can be switched freely. Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l.

MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful 2

 

Rich Human-machine Interface

  • 2.5-inch high-definition color screen.
  • Simultaneously display the concentrations of 6 types of gases, repeatedly display the concentration of single-channel gases in large font, and display the real-time curve.

MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful 3

 

Diversified Data Communication Methods

  • It is possible for the real-time monitoring via the wired or remote wireless transmission, and network transmission.
  • Three-wire system 4 ~ 20mA standard signal and standard bus RS485 (modbus-RTU) simultaneous output.
  • It is possible to select frequency output 200-1000Hz, Hart protocol signal, 1 ~ 5V output, two-wire system 4 ~ 20mA, SMS alarm, wireless transmission (2 ~5 km or unlimited distance).
  • It is compatible with secondary instrument, data acquisition module, PLC, DCS system, and it is possible to drive the related equipment.

MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful 4

 

Powerful and Convenient Humanized Function

  • Multiple alarm modes, and multi-directional and three-dimensional indication alarm states. It includes: 2 sets of relay switch output, sound & light alarm (optional configuration), and display screen visual alarm. Alarm types include: concentration alarm, and failure alarm. Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm.
  • Zero-point automatic tracking; long-term use will not be affected by the zero drift.
  • Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements.
  • Log recording Record the calibration logs, repair logs, failure history, failure countermeasure solutions, sensor service life due reminder, and function of reminder for the time of next concentration calibration.
  • Data recovery function; in case of mis-operation, it is possible to select partial or full recovery.
  • Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may be caused by human factors.

MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful 5

 

Infrared Remote Control

  • Standard configuration includes the infrared remote control, it is possible for one-key operation via infrared remote control function key, which can achieve the operation without opening the cover under hazardous situations.such as: the functions like modification of the alarm point, density calibration, zero-point calibration, noise reduction, restoring the factory setting, and so on.

MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful 6

 

Multiple Optional Functions, Meet the Personalized Needs

Integrated sound & light alarming device, split-type sound & light alarming device,
  • 24V DC stabilized voltage power supply.

Wireless transmission

  • It is possible to transfer data wirelessly to the cell phone, remote monitoring center, monitoring computers and other monitoring equipment, which will utilize the upper-level host to realize the functions of data analysis, storage, printing or the like on the computer.
Pretreatment system
  • Room temperature and high humidity pretreatment system
  • High temperature and high humidity pretreatment system
  • High temperature and high humidity and high dust pretreatment system
Accessory for connection with computer for monitoring
  • Free upper-level host software, RS485 / RS232 converter
  • For laptop without RS232 interface, USB / RS232 converting and connecting cable is needed, if the network transmission is needed, TCP / IP converter will be further needed.
Installation type accessories
  • wall mounting bracket;
  • mounting clips for fixation on the pipes (1/2", 3/4" pipe);
  • stainless steel threaded welding seat or flange to be installed on the pipeline(it is necessary to mark the flange or pipe size, such as DN50, DN15 ...);
  • Rain cover;
  • 24VDC or 220AC sampling pump (sampling distance is 10 m);
  • vacuum pump (sampling distance is greater than 40 m);
  • 24V switching power supply;
  • pressure reducing valve;
  • flow meters.

 

SPECIFICATION

 

Gases to be detected Arbitrary combination of multiple types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive
gases, TVOC, and so on.
Optional configuration: it is possible to simultaneously detect any 1 ~ 6 gases as well as temperature and humidity.
Application scenarios All the cases which requires the fixed installation, and online detection of gas concentrations such as petroleum, chemical,
pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be
customized.
Resolution 0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm),
0.1ppm (0 ~ 1000 ppm),
1ppm (0 ~ 10000 ppm or more),
0.01 mg/l (0 ~ 200 mg/l),
0.1% LEL,
0.01%,
0.001% Vol
Detection principle Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of
gas, range, field environment and user demand.
Sensor service life Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected;
Infrared principle: 5 ~ 10 years;
Catalytic combustion: 3 years;
Thermal conductivity: 5 years.
Allowable error ≤±1% F.S (other or higher precision levels can be customized)
Linearity ≤±1% Repeatability ≤±1% Uncertainty ≤±1%
Response time T90≤20 seconds Recovery time ≤30 seconds
Signal output Bus system RS485 (RTU), three (four) wire system 4 ~ 20mA, optional configuration: 0 ~ 20mA, 1 ~ 5V, 0 ~ 5V, 0 ~ 10V, wireless
transmission, network transmission, and SMS alarms.
Working environment Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH (regular) non-condensing case .
It should be customized in the case of use in the condensing case, or the use environment should be specified at the time of
ordering. Range of working pressure: atmospheric pressure ± 30%, some sensors can detect under the pressure of 7 kg
Display method 2.5-inch high-definition color screen for field display, it is possible to select no field display, or the optional configuration
of MIC2000 controller for remote display, control, and alarm
Working voltage 12 ~ 30VDC direct current, the standard power supply for a single equipment is 24V, DC stabilized voltage switching power supply
of 1A or greater than 1A.
Power consumption Instantaneous maximum electric current: electrochemical principle: 60 mA, catalytic or infrared principle: 120 mA
Power supply reference The switching power supply of 24V, 2.1A is possible to drive 40 units of toxic gas detector, or 15 units of flammable, infrared
gas detector.
Working method Fixed type installation, online detection, diffusion type measurement; and it is possible to select the measurement of pipeline
type, flow-through type, and pump-suction type.
Installation method Pipeline type, and wall mounting type. The working pressure of the pipeline type is ± 30% of atmospheric pressure, and when
exceeded this range, it is necessary for the depressurization treatment.
Alarm mode The default option is 1-way, and it is possible to select 3-way passive contact (dry contact) output, level III alarm, and the
alarm point can be set. Field sound & light alarm (optional configuration).
Connecting cable Adopted 4 ~ 20mA three-core shielding cable, adopted four-core for RS485, when the distance exceeded 100 meters, the single wire
diameter ≥1.5mm; and the shielding layer will be connected to the earth.
Protection level IP66, prevent the water splash and short-period rain
Explosion-proof type Explosion suppression type
Explosion-proof mark ExdⅡCT6
Exterior dimensions 210×170×85mm (L×H×W)
Weight 1.8Kg
Standard accessories Manual, qualification certificate, warranty card, outer packaging box
Optional items Integrated sound & light alarming device, split-type sound & light alarming device, 24V DC stabilized voltage power supply,
accessory for connection with computer for monitoring: free upper-level host software, RS485 / RS232 converter.
For laptop without RS232 interface, USB / RS232 converting and connecting cable is needed, if the network transmission is needed,
TCP / IP converter will be further needed.Larger capacity accessory for the data storage: SD card.
Wireless transmission Optional function is possible to transfer data wirelessly to the cell phone, remote monitoring center, monitoring computers and
other monitoring equipment, which will utilize the upper-level host to realize the functions of data analysis, storage, printing
or the like on the computer
Pretreatment system Optional configuration: room temperature and high humidity pretreatment system, high temperature and high humidity pretreatment
system, high temperature and high humidity and high dust pretreatment system
Temperature and Humidity measurement Optional: temperature: -40 ℃ ~ + 120 ℃, accuracy: 0.3 ℃
Humidity: 0-100% RH, accuracy: 3% RH
Installation type accessories Optional configuration: wall mounting bracket, mounting clips for fixation on the pipes (1/2", 3/4" pipe), stainless steel
threaded welding seat or flange to be installed on the pipeline (it is necessary to mark the flange or pipe size, such as DN50,
DN15 ...),
rain cover, 24VDC or 220AC sampling pump (sampling distance is 10 m), vacuum pump (sampling distance is greater than 40 m),
24V switching power supply, pressure reducing valve, flow meters.

 

APPLICATION  

 

All the cases which requires the fixed installation, and online detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.

 

MIC600 Ch4 Methane Gas Detector Online Fixed Composite Type Toxic And Harmful 7

Contact Details
Beijing HiYi Technology Co., Ltd

Contact Person: Lisa Niu

Tel: 86-15699785629

Fax: +86-010-5653-8958

Send your inquiry directly to us (0 / 3000)