Product Details:
|
Name: | HiYi Laser Sensor Wireless Printer Large Storage PM1.0 PM2.5 PM10.0 Portable Dust Monitor | Gas: | PM0.3 PM0.5 PM1.0 PM2.5 PM5.0 PM10.0 (optional) |
---|---|---|---|
Data Storage: | 100, 000 Entries | Display: | 2.5-inch TFT LCD Display |
Output Signal: | Wireless Transmission And Print Function(Optional) | Charging Time: | 8 Hours |
Protection Level: | IP67 | Alarm Mode: | Audible-visual Alarm,Vibration Alarm,Voice≥75dB@25cm |
High Light: | PM10.0 Portable Dust Monitor,PM2.5 Portable Dust Monitor,PM1.0 Portable Dust Monitor |
HiYi Laser Sensor Wireless Printer Large Storage PM1.0 PM2.5 PM10.0 Portable Dust Monitor
HiYi MS600 Portable Gas Detector
6 in 1 | Internal Pump | Wireless Printer | Large Data Storage
Clearance measurement was never this easy and convenient!
The MS600 measures up to 8 gases, including toxic, flammable gases and vapors, and oxygen all at once—either in pump or diffusion mode.
Innovative signaling design and handy wizard functions ensure complete safety throughout the process.
1.Specially designed for use with its internal pump, optimized for your requirements
The MS600 is equipped with a very powerful internal pump. It can be connected with hoses of up to 45 meters in length. This means the pump is only operated when you actually need it.
That saves energy, reduces wear and tear, and thereby extends the lifespan of the pump.
2.Compact Design, Easy to Use
Handy and durable, the MS600 is intuitive to operate single-handedly using three function keys. The easy-to-read color display clearly lays out all the information for you.
Thanks to its compact and robust construction, the device can withstand even the harshest conditions.
3.Large Data Storage Management, Release and Documentation In No Time
Standard configuration is the data storage capacity for 100, 000 entries, SD Memory is optional.
Real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored.
It is supported to use the local host to view, and delete data, and upload the data via USB/RS232 interface to the computer for data analysis or printing.
4.Clear Signaling Design
The signal system of the MS500 is based on a clear color code: sound & light alarm, vibration alarm, display screen visual alarm.These are also documented in the data logger.
5.Economical Calibration Management
The deviation of the concentration which was detected out by the instrument from the standard gas concentration can be corrected by calibrating the concentration or changing the display coefficients.
6.Inductive Charging Protects Against Wear and Tear
The MS600 features inductive charging.
This makes it easier to operate and increases the lifespan of the device.
Issues like corrosion and contact problems in the charging cradle are a thing of the past. You can charge (outside of explosion-hazard zones) and measure at the same time.
Gases to be detected |
Arbitrary combination of 1 ~ 6 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements. |
|||||
Application scenarios | All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on. | |||||
Detection range | 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized. | |||||
Resolution |
0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 10000 ppm or more), 0.01 mg/l (0 ~ 200 mg/l), 0.1% LEL, 0.01%, 0.001% Vol |
|||||
Detection principle | Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand. | |||||
Sensor service life | Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years. | |||||
Allowable error | ≤±1% F.S (other precision levels can be customized) | |||||
Linearity | ≤±1% | Repeatability | ≤±1% | Uncertainty | ≤±1% | |
Response time | T90≤20 seconds | Recovery time | ≤30 seconds | |||
Working environment | Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment. | |||||
Sample gas temperature | -40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃. | |||||
Temperature and humidity measurement | Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH | |||||
Power supply | 3.6VDC, 6000mA high capacity rechargeable polymer battery | |||||
Display mode | 2.5-inch high-definition color screen | |||||
Detection mode | Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass | |||||
Alarm mode | It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm. | |||||
Communication interface | USB (charging and communication), optional: RS232, infrared communication, automatic recognition | |||||
Data storage | Standard configuration is the data storage capacity for 100, 000 entries; SD card storage function is optional configuration | |||||
Protection level | IP67 | |||||
Explosion-proof type | Intrinsically safe type | |||||
Explosion-proof mark | Exia II CT6 | |||||
Exterior dimensions | 180×78×33mm (L×W×H) | |||||
Weight | 350g | |||||
Standard accessories | Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case, belt clip, humidity dust filter | |||||
Optional items | Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter), 0.4 meter stainless steel sampling handle (with dust filter, not retractable), high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, multiple humidity dust filter, hanging rope, CD-ROM (upper level computer communication software), SD card storage, wireless data communications, external mini wireless infrared printer | |||||
Detection mode | Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass | |||||
Alarm mode | It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm. | |||||
Communication interface | USB (charging and communication), optional: RS232, infrared communication, automatic recognition | |||||
Data storage | Standard configuration is the data storage capacity for 100, 000 entries; SD card storage function is optional configuration | |||||
Protection level | IP67 | |||||
Explosion-proof type | Intrinsically safe type | |||||
Explosion-proof mark | Exia II CT6 | |||||
Exterior dimensions | 180×78×33mm (L×W×H) | |||||
Weight | 350g | |||||
Standard accessories | Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case, belt clip, humidity dust filter | |||||
Optional items | Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter), 0.4 meter stainless steel sampling handle (with dust filter, not retractable), high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, multiple humidity dust filter, hanging rope, CD-ROM (upper level computer communication software), SD card storage, wireless data communications, external mini wireless infrared printer. |
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Contact Person: Lisa Niu
Tel: 86-15699785629
Fax: +86-010-5653-8958