|
Product Details:
|
Name: | Portable Multi Gas Detector | Gas: | H2S O2 CO Ex (optional) |
---|---|---|---|
Data Storage: | 100, 000 Entries | Display: | LCD Display |
Response Time: | <30s | Charging Time: | 4h-6h Standby Time, Continuous Use For More Than 10 Hours At A Full Charge |
Protection Level: | IP65 | Alarm Mode: | Sound, Lighting, Vibration |
Size: | 130*68*34 Cm | Weight: | 0.2 Kg |
Highlight: | HiYi Multi Gas Leak Detector,IP65 Multi Gas Leak Detector,MS104K Toxic Gas Detector |
HiYi Large Storage Buzzer Alarm H2S O2 CO Ex Mining Bio Gas Portable Multi Gas Detector
Portable Multi Gas Detector
1-- 4 Toxic Gas Detector
Clearance measurement was never this easy and convenient!
The MS104K measures up to 4 gases, including toxic, flammable gases and vapors, and oxygen all at once—either in pump or diffusion mode.
Innovative signaling design and handy wizard functions ensure complete safety throughout the process.
1.Multi-gas made simple, easy to wear, slim and compact
It is possible to simultaneously detect 1 ~ 4 types of gases, and the units can be switched freely .
Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l.
2.Compact design, easy to use
Handy and durable, the MS104 is intuitive to operate single-handedly using three function keys.
The easy-to-read color display clearly lays out all the information for you. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.
3.Large Data Storage Management, release and documentation in no time
Standard configuration is the data storage capacity for 100, 000 entries.
Real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored.
It is supported to use the local host to view, and delete data, and upload the data via USB interface to the computer for data analysis or printing.RS485 communication is an optional configuration.
4.Clear signaling design
The signal system of the MS104K is based on a clear color code: sound & light alarm, vibration alarm, display screen visual alarm.These are also documented in the data logger.
5.Economical Calibration Management
The deviation of the concentration which was detected out by the instrument from the standard gas concentration can be corrected by calibrating the concentration or changing the display coefficients.
6.Inductive charging protects against wear and tear
The MS104K features inductive charging.
This makes it easier to operate and increases the lifespan of the device.
Issues like corrosion and contact problems in the charging cradle are a thing of the past. You can charge (outside of explosion-hazard zones) and measure at the same time.
Gases to be detected |
Arbitrary combination of 1 ~ 4 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements. |
||||
Application scenarios | All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on. | ||||
Detection range | 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/l, 100%LEL, 20%, 50%, 100%Vol can be selected; and other ranges can be customized. | ||||
Resolution |
0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 1000 ppm or more), 0.01 mg/l (0 ~ 200% mg/l), 0.1% LEL, 0.01%Vol, 0.001% Vol |
||||
Detection principle | Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand. | ||||
Sensor service life | Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years. | ||||
Maximum allowable error | ≤±3% F.S (higher precision levels can be customized) | ||||
Linearity | ≤±2% | Linearity | ≤±2% | Linearity | ≤±2% |
Response time | T90≤30 seconds | Recovery time | ≤30 seconds | ||
Working environment | Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH | ||||
Sample gas temperature | -40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 400 ℃ or higher. | ||||
Temperature and humidity measurement | Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH | ||||
Power supply | 3.7VDC, 3000mA high capacity rechargeable polymer battery | ||||
Display mode | 2.31-inch high-definition color screen | ||||
Detection mode | Diffusion type measurement. The calibrated flow rate is 500 ml/minute. | ||||
Alarm mode | It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm. | ||||
Communication interface | USB (charging and communication), optional: RS485 communication interface | ||||
Data storage | Standard configuration is the data storage capacity for 100, 000 entries | ||||
Protection level | IP65 | ||||
Explosion-proof type | Intrinsically safe type | ||||
Explosion-proof mark | Exia II CT4 Ga | ||||
Exterior dimensions | 130×68×34mm (L×W×H) | ||||
Weight | 200 g | ||||
Standard accessories | Manual, qualification certificate, warranty card, USB charger (including the data cable), belt clip, colorful packaging box (optional high-grade aluminum instrument case) | ||||
Optional items | Temperature and humidity measurement function, external gas sampling pump, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter), 0.4 meter stainless steel sampling handle (with dust filter, not retractable) |
The detector is widely used in petroleum, chemical industry,environmental protection, metallurgy, refining, gas, biochemical medicine, agriculture, fire protection, Archaeology and other industries and places that need safety monitoring for toxicity and harmfulness, explosion prevention. The detector can effectively predict the concentration of dangerous gases and alarm, so as to ensure the safety of workers and production equipment.
Contact Person: Lisa Niu
Tel: 86-15699785629
Fax: +86-010-5653-8958