Product Details:
|
Model: | UVOZ-3300C | Light Source Life: | Approx. 30,000 - 50,000 Hours |
---|---|---|---|
Optional Ranges: | 0-200g/Nm3, 0-100g/Nm3, 0-50g/Nm3, 0-1000ppm | Content Interface: | Ozone Concentration, Temperature, Pressure |
Dimensions: | 230mm (H) X 330mm (W) X 150mm (D) | Temperature: | -20 To 50°C |
High Light: | wall mounted ozone o3 detector,uv light absorption ozone o3 detector,uv light absorption o3 gas detector |
UVOZ-3300C Ozone Gas Analyzer
The UVOZ-3300C ozone gas analyser calculates the current ozone concentration by measuring the change in light signal intensity before and after ozone absorption of UV light. The equipment uses an advanced dual-light UV light source system with an intelligent lamp management system, which enables the UV lamp to reach the measurement state quickly after switching on. It is mainly used for continuous detection of ozone gas in various industrial environments, and can also be used to detect ozone gas in operating pipelines, vessels and other environments. It is widely used in pharmaceutical, chemical, municipal and wastewater treatment industries for the measurement of ozone generator outlet concentration and ozone generator output.
The ozone analyser has a touch screen operator interface with real time display of ozone gas concentration, with pressure and temperature compensation and display, and can be set for automatic zero time and manual zeroing mode. High concentration (g/Nm3) range with flow input and real time display of ozone generator output. Two sets of relay signal outputs are available, allowing the user to choose between high and low alarm point signal output connections. The core component adopts UV long life light source system with high transmittance quartz sheet to ensure the stability of the zero point and prevent the zero point drift from affecting the accuracy of the detection concentration. According to the foreign light cell technology design of pressure-resistant, impact-resistant independent light cell structure, zero calibration operation gas flow, pressure, flow rate remains unchanged, to prevent the impact of airflow on the zero calibration, without closing the ozone inlet can complete the zero calibration operation, to ensure that the equipment can be 24 hours a day continuous operation.
Model | UVOZ-3300C |
Measuring range | 0-300g/Nm3 |
Optional ranges | 0-200g/Nm3, 0-100g/Nm3, 0-50g/Nm3, 0-1000ppm |
Light source life | approx. 30,000 - 50,000 hours |
Sampling method | positive pressure sampling, negative pressure sampling (optional) |
Display interface | 4.3" touch screen operator interface |
Content interface | ozone concentration, temperature, pressure |
Auxiliary functions | Temperature compensation, pressure compensation |
Display units | g/Nm3, mg/NL, %WT optional |
Display resolution | 0.01g/Nm3 |
Gas flow | 0.5L ± 0.2L/min |
Input pressure | <0.1 MPa |
Concentration error | 0.5% FS max |
Linearity error | 0.5% FS max |
Zero point drift | <±0.3%.FS |
Response time | 0.03 s for signal, 0.3 s for display |
Ambient temperature | -20 to 50°C |
Piping connection | Quick screw (stainless steel) |
Tandem sample aperture | Φ8 (8mm*6mm) (optional) |
Bypass sampling aperture | Φ6 (6mm*4mm) |
Communication method | RS-485 |
Output mode | 4-20mA (active) |
Relay signal | relay signal for high alarm point, relay signal for low alarm point |
Power supply | AC 110-220V |
Dimensions | 230mm (H) x 330mm (W) x 150mm (D) |
Note | 1mg/L = 1g/m3 = 467PPM. |
Free warranty | 24 months (mainframe sensor) |