Product Details:
|
| Highlight: | pid thermostatic water tank,11l thermostatic water tank,36l lab thermostatic water tank |
||
|---|---|---|---|
The MS900 Handheld Headspace Gas Tester is designed for evaluating oxygen and carbon dioxide concentrations inside sealed packaging containers, including selected coffee cans, beverage packages, bottles and other rigid packaging formats.
The instrument measures the headspace gas composition using a built-in sampling pump and needle-based gas extraction system. This allows a small sample to be collected from a suitable package access point for analysis.
The MS900 is equipped with an electrochemical oxygen sensor with a 0–100 vol.% range and an infrared carbon dioxide sensor with the same concentration range.
Oxygen measurement requires less than 5 mL of sample gas, with a specified measurement time of 15 seconds or less. The CO2 channel requires less than 15 mL and provides results within 20 seconds or less.
For packages containing oxygen, carbon dioxide and nitrogen as the relevant main gases, the instrument calculates nitrogen concentration from the two measured values.
A built-in pressure sensor also provides a measurement function for assessing package pressure or vacuum conditions, although the numeric pressure-measurement range is not separately specified.
The lightweight 450 g housing supports convenient use during product inspection, while the quick-insert needle protection cover helps improve handling safety.
A 6,800 mAh lithium battery, 2,000-group memory and USB connection support portable testing and subsequent measurement data management.
Handheld gas analysis for sealed packaging containers.
Suitable for coffee and beverage packaging inspections.
Oxygen and carbon dioxide measurement.
Calculated nitrogen result.
Electrochemical and infrared sensing technologies.
O2 and CO2 measurement ranges of 0–100 vol.%.
Small sample volume requirement.
Needle-based gas extraction.
Built-in sampling pump.
Integrated pressure sensing.
Protective cover for sampling needle.
Convenient one-handed testing.
One-button operation and calibration.
Two-point calibration method.
Chinese/English interface.
Automatic result recording.
Storage for 2,000 test records.
USB import/export function.
Power-off memory.
Remote system upgrade and maintenance.
Rechargeable lithium battery.
Check residual oxygen and carbon dioxide concentrations in suitable sealed coffee containers.
Measure internal headspace gas composition during product packaging quality checks.
Perform gas analysis of suitable sealed beverage packaging using an appropriate sampling access method.
Evaluate internal gas concentrations in compatible sealed containers.
Support headspace gas inspections of appropriate multilayer carton packages, including Tetra Pak-style packaging.
Carry out selected packaging gas inspections during product storage and quality verification.
| Technical Item | Value |
|---|---|
| Product Model | MS900 |
| Product Type | Handheld Packaging Headspace Gas Tester |
| Gas Measurement | Oxygen and Carbon Dioxide |
| Nitrogen | Calculated from O2 and CO2 |
| Oxygen Sensor Type | Electrochemical |
| Oxygen Range | 0–100 vol.% |
| Oxygen Accuracy | ≤±0.2% |
| Oxygen Resolution | 0.01 vol.% |
| Required O2 Sample | <5 mL |
| O2 Measurement Time | ≤15 seconds |
| Oxygen Sensor Service Life | Approximately 2 years in air |
| CO2 Sensor Type | Infrared |
| Carbon Dioxide Range | 0–100 vol.% |
| Carbon Dioxide Accuracy, 0–50% | ≤±2% |
| Carbon Dioxide Accuracy, 50–100% | ≤±3% |
| Carbon Dioxide Resolution | 0.01 vol.% |
| Required CO2 Sample | <15 mL |
| CO2 Measurement Time | ≤20 seconds |
| CO2 Sensor Life | >10 years |
| N2 Range | 0–100 vol.%, calculated |
| Sampling Method | Integrated pump |
| Sampling Access | Needle-based |
| Needle Protection | Quick-insert protective cover |
| Pressure Sensor | Built-in |
| Calibration | Two-point |
| Intake Pressure Specification | 700–1,500 mbar absolute |
| Storage | 2,000 groups |
| USB Data Transfer | Supported |
| Language Options | Chinese and English |
| Automatic Shutdown | Supported |
| Automatic Memory | Supported |
| Power-Off Data Memory | Supported |
| Remote Maintenance and Upgrade | Supported |
| Battery Capacity | 6,800 mAh |
| Battery Type | Lithium |
| Working Temperature | 0–40°C |
| Product Size | 180 × 106 × 80 mm |
| Weight | 450 g |
The MS900 uses a sampling needle to collect headspace gas.
For rigid containers such as metal cans, bottles and multilayer cartons, a compatible sampling access arrangement is necessary. The supplied information does not specify a dedicated can-piercing attachment or universal adapter.
Sampling procedures should also account for the available headspace volume and package pressure.
The MS900 combines portable gas composition testing, low-volume sampling and convenient data management for coffee, beverage and container packaging applications.
Its O2 and CO2 sensors allow manufacturers to check important headspace parameters without relying exclusively on laboratory-based gas analysis equipment.
Contact Person: Lisa Niu
Tel: 86-15699785629
Fax: +86-010-5653-8958