Send Message
Home ProductsWater Quality Analyzer

Bacterial And Microbial Atp Fluorescence Detector Surface Cleanliness Testing

Customer Reviews
High quality machine, it works wonderful and quiet. very good service.

—— Nor

Excellent Product, popular in the team.

—— Fernando

I'm Online Chat Now

Bacterial And Microbial Atp Fluorescence Detector Surface Cleanliness Testing

Bacterial And Microbial Atp Fluorescence Detector Surface Cleanliness Testing
Bacterial And Microbial Atp Fluorescence Detector Surface Cleanliness Testing

Large Image :  Bacterial And Microbial Atp Fluorescence Detector Surface Cleanliness Testing

Product Details:
Place of Origin: China
Brand Name: HiYi
Certification: CE
Model Number: HY-ATP
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: paper case
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

Bacterial And Microbial Atp Fluorescence Detector Surface Cleanliness Testing

Description
Product Name: ATP Fluorescence Detector High Sensitivity: 10-15~10-18 Mol
Feasibility: Number Of Microorganisms In The Reaction Can Be Obtained Indirectly Operability: The ATP Rapid Cleanliness Detection Operation Is Very Simple
Better Experience: The Test Tube Adopts A Pluggable And Flexible Design Practicability: Upper And Lower Limits Can Be Set
High Light:

bacterial atp fluorescence detector

,

surface cleanliness testing atp fluorescence detector

,

microbial fluorometric detector

ATP fluorescence detector

 

OVERVIEW

 

The device is a brand new upgraded product with a large touch screen instead of traditional buttons. The operation uses a biochemical reaction method to detect ATP content. The ATP fluorescence detector is based on
the principle of firefly luminescence and uses the "luciferase-luciferin system" to quickly detect adenosine triphosphate (ATP). The ATP swab contains a reagent that can lyse the cell membrane, which can release ATP
from the cell, react with the specific enzyme contained in the reagent to produce light, and then use a fluorometer to detect the luminescence value. The number of microorganisms is proportional to the luminescence value. Since all living organisms contain a constant amount of ATP, the ATP content can clearly indicate the residual amount of microorganisms
and other organisms in the sample, which is used to judge the sanitary condition. 

 

Bacterial And Microbial Atp Fluorescence Detector Surface Cleanliness Testing 0

 

FEATURES & BENEFITS

 

Instrument characteristics:

  • Practicability —— The upper and lower limits can be set according to the requirements of environmental testing, so that data can be quickly evaluated and early warning, and surface cleanliness can be quickly screened.
  • High sensitivity —— 10-15~10-18 mol
  • Fast speed——the conventional culture method is more than 18-24h, while ATP only takes more than ten seconds.
  • Feasibility——There is a clear correlation between the number of microorganisms and the ATP contained in the microorganisms. By detecting the ATP content, the number of microorganisms in the reaction can be obtained indirectly
  • Operability ——Traditional cultivation methods need to be operated by trained technicians in the laboratory; and the ATP rapid cleanliness detection operation is very simple, and only simple training can be performed by ordinary staff on-site.
  • Better experience —— The test tube adopts a pluggable and flexible design, which can be cleaned regularly for long-term use and prolong the life of the instrument. 

 

SPECIFICATION

 

Random configuration:

ATP fluorescence detector (handheld) host, aluminum alloy suitcase, drive U disk, PC data cable, data analysis software, operation manual.
 
The main parameters:
  • Display: 3.5-inchhigh-precision graphic touch screen
  • Processor: 32-bithigh-speed data processing chip
  • detection accuracy:1×10-18mol
  • Coliform group: 1-106cfu
  • detection range: 0 to 9999RLUs
  • Detection time: 15 seconds
  • Detection interference:±5﹪ or ±5 RLUs
  • Operating temperature range: 5℃ to 40℃
  • Operating humidity range: 20—85﹪
  • ATP recovery rate: 90-110%
  • Detection mode: RLU, coliform screening
  • 50 user ID settings
  • T​he number of settable result limits: 251
  • automatically judge qualified and unqualified
  • automatic statistics of pass rate
  • built-in self-calibration light source
  • 30 seconds self-check after booting
  • Equipped with a miniUSB interface, the results can be uploaded to the PC
  • Equipped with dedicated software driver U disk instead of traditional CD
  • Instrument size (W×H×D):188 mm×77mm×37mm
  • Use rechargeable lithium battery without battery replacement
  • Standby state (20℃): 6months
  • operation manual
  • stable liquid luciferaseWetted integrated collection swab
APPLICATION  

 

ATP fluorescence detector is widely used in: bacterial and microbial testing, medicine and hygiene, food safety, market law enforcement, surface cleanliness testing, medical and epidemic prevention, water quality and water administration, production line hygiene, industrial water treatment, environmental protection testing, customs entry and exit quarantine and Various industries such as other law enforcement agencies. 

Contact Details
Beijing HiYi Technology Co., Ltd

Contact Person: Lisa Niu

Tel: 86-15699785629

Fax: +86-010-5653-8958

Send your inquiry directly to us (0 / 3000)