Product Details:
|
Working Time: | 20 Minutes | Work Temperature: | 0-40 Degrees |
---|---|---|---|
Capacity: | 0-50ML,2-100ML,5-200ML,10-300ML,20-500ML,20-1000ML,50-2000ML,100-3000ML | Random Amplitude Lever (mm): | Φ2,Φ3,Φ6,Φ8,Φ10,Φ15,Φ20,Φ25 |
Plate Material: | Piezoelectric Ceramic Plate | Power: | AC220V |
Highlight: | power continuous ultrasonic cell crusher,power adjustable ultrasonic cell crusher,ISO13485 Ultrasonic Cell Crusher |
UCC Series Ultrasonic Cell Crusher
Ultrasonic cavitation in liquid. Ultrasonic cavitation refers to the dynamic process of growth and collapse when the sound pressure reaches a certain value when the cavitation bubble in the micro gas core existing in liquid vibrates under the action of sound wave. When the sound pressure reaches a certain value, the bubble will expand rapidly and then suddenly close. Shock waves will be generated when the bubble closes. This series of dynamic processes, such as expansion, closure and oscillation, are called ultrasonic cavitation.
1. Set /OK button can SET the time and confirm the storage function;
2. Press SET/OK button to SET the total ultrasonic time in pulse mode, on pulse ultrasonic time, and off pulse in turn
Ultrasonic time;
3. Run/Stop key has two functions, namely start pulse ultrasound and close pulse ultrasound (off and reset)
Pulse ultrasonic total time), in Pulse ultrasonic mode, press the PAUSE button to PAUSE the current running time
To continue running the current task by pressing Pause again.
4. MODEL (Continuous Ultrasonic Mode Start Button) When the pulsed ultrasound mode is changed to continuous ultrasound mode, press the (RUN/STOP) button to start the continuous ultrasonic mode, otherwise from the continuous ultrasonic mode
Formula is converted to pulsed ultrasonic mode, then there is no need to press the (RUN/STOP) key.
Model | KC-150W | KC-250W |
KC-300W |
KC-450W | KC-600W |
KC-900W |
KC-1200W |
KC-1800W |
Power (Continuous Adjustable) | 1.5-150W | 2.5-250W | 3.0-300W | 4.5-450W | 10-600W | 10-900W | 20-1200W | 50-1800W |
Crushing capacity
|
0-50ML | 2-100ML | 5-200ML |
10- 300ML |
20- 500ML |
20- 1000ML |
50- 2000ML |
100- 3000ML |
Frequency (KHz) |
19.86- 20.6 |
19.86- 20.6 |
19.86- 20.6 |
19.86- 20.6 |
19.86- 20.6 |
19.86- 20.6 |
19.86- 20.6 |
19.86- 20.6 |
Random amplitude lever (mm)
|
Φ2 | Φ3 | Φ6 | Φ8 | Φ10 | Φ15 | Φ20 | Φ25 |
Optional horn (mm)
|
Φ2/3/6/8 | Φ2/3/6/8 | Φ2/3/6/10 | Φ2/3/6/8 10/ |
Φ2/3/6/8 10 |
Φ2/3/6/8 10/18 |
Φ3/6/8/10 13/15/18 |
Φ3/6/8/10 13/15/18/20 |
It is a multifunctional and multipurpose instrument for ultrasonic treatment of substances by using ultrasonic to produce cavitation effect in liquids. It can be used for the crushing of a variety of animal and plant cells and virus cells. It can also be used for emulsification, separation, extraction and accelerating chemical reactions. It is widely used in biology, medicine, chemistry, agriculture, physics and other fields.