The MIC2000 Multi-Channel Gas Alarm Controller is designed for centralized monitoring, alarm management and control of fixed gas detection systems. It accepts both 4-20mA analog signals and RS485 digital signals, allowing multiple gas detectors and industrial transmitters to be connected to one central monitoring unit.
The controller can be configured with 1 to 32 channels of 4-20mA input while simultaneously communicating with up to 255 RS485 devices, depending on system configuration. In addition to gas detectors, compatible 4-20mA transmitters such as temperature, humidity, pressure, wind speed and dust sensors can also be integrated.
A 3.5-inch HD color screen displays real-time readings, alarm information and historical records. Multiple display modes, relay outputs, data storage and optional remote communication make the MIC2000 suitable for industrial plants requiring centralized safety supervision and automatic equipment control.
Supports simultaneous 4-20mA and RS485 signal input
1–32 configurable 4-20mA input channels
Supports up to 255 RS485-connected devices
Standard MODBUS communication
3.5-inch HD color display
Chinese and English interface
Compatible with gas, temperature, humidity, pressure, wind speed and dust transmitters
Multiple selectable engineering units
Large-capacity historical data recording
User-defined data logging interval
Local record viewing and deletion
Three display modes for different monitoring requirements
Real-time trend curve and historical graph display
Three-stage audible and visual alarm
Independent high and low alarm settings for each channel
Standard relay control outputs
Automatic open-circuit and short-circuit detection
Optional Ethernet communication
Optional PC monitoring software
Optional remote wired or wireless transmission
Optional backup DC24V power supply
The MIC2000 provides several screen layouts to make multi-channel monitoring easier.
Available display modes include:
Six-channel simultaneous concentration display
Single-channel large-font cyclic display
Real-time trend curve
Channels can be switched automatically or manually. Maximum values, minimum values, gas names and historical trend information can also be displayed according to configuration.
The internal data logging function can store measurement values, alarm events and time information. Users can choose to record continuous concentration data or alarm events only.
The controller provides multi-stage gas alarm management for connected detectors.
Each monitoring channel can be assigned independent alarm thresholds. When the measured concentration reaches a preset alarm level, the MIC2000 can activate:
Audible alarm
Visual alarm
Relay output
Ventilation fan
Solenoid valve
External warning device
Other connected control equipment
Standard relay contacts support normally open and normally closed operation.
The MIC2000 can communicate with external monitoring systems using standard industrial interfaces.
Supported or optional interfaces include:
RS485
MODBUS protocol
4-20mA output
Ethernet
RS232 conversion
PC monitoring software
Remote transmission can be used to send real-time field data to a control room, monitoring computer or other centralized platform.
Depending on configuration, communication can be established through wired data transmission, LAN, Internet or wireless networks.
| Parameter | Specification |
|---|---|
| Model | MIC2000 |
| Product Type | Multi-Channel Gas Alarm Controller |
| Analog Input | 1–32 channels, 4-20mA |
| Digital Input | RS485, up to 255 probes/devices |
| Output Communication | RS485, standard MODBUS protocol |
| Optional Output | Ethernet, configurable 4-20mA output |
| Display | 3.5-inch HD color screen |
| Display Range | 0–99999 |
| Resolution | 1 / 0.1 / 0.01 / 0.001 selectable |
| Display Accuracy | ±0.1% FS |
| Display Modes | Six-channel display / single-channel large-font cycle / trend curve |
| Control Outputs | Standard 4-channel control; 8 / 12 / 16-channel options |
| Alarm Type | Audible and visual, three-stage alarm |
| Relay Output | 4 groups standard + common alarm relay |
| Standard Relay Capacity | 3 A / 32 VDC or 3 A / 220 VAC |
| Common Alarm Contact | 12 A / 32 VDC or 7 A / 240 VAC |
| Automatic Diagnosis | Open-circuit, short-circuit, detector status and function monitoring |
| Operating Temperature | -40°C to +70°C |
| Relative Humidity | 0–95% RH, non-condensing |
| Standard Power | 220 VAC / 50 Hz |
| Optional Power | 24 VDC, 2 A / 5 A / 10 A |
| Backup Power | DC24V 5Ah optional |
| Maximum Consumption | Approx. 2.5 W per channel |
| 2/4/8-Channel Size | 330 * 255 * 95 mm |
| 16/24-Channel Size | 420 * 305 * 95 mm |
| 32-Channel Size | 540 * 305 * 95 mm |
The controller supports multiple units for different detector and transmitter applications, including:
ppm, %LEL, %Vol, mg/m³, μg/L, pphm, °C, %RH, Pa, kg, PSI and m/s
The MIC2000 is suitable for centralized monitoring systems in:
Oil and gas facilities
Petrochemical plants
Chemical production
Warehouses
Gas storage areas
Industrial workshops
Power plants
Wastewater treatment facilities
Pharmaceutical production
Laboratories
Environmental monitoring projects
Utility facilities
Confined-space safety systems
The MIC2000 combines multi-channel signal acquisition, centralized alarms, relay control, historical data storage and remote communication in one wall-mounted controller.
Its ability to accept both RS485 and 4-20mA signals makes it especially useful for mixed detector networks where different types of sensors and transmitters need to be managed through one central monitoring platform.