Product Details:
Place of Origin: China
Brand Name: HiYi
Certification: CE
Model Number: MIC200-IR3
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD 500-- 3000/set
Packaging Details: color box
Delivery Time: 3-7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 10000 set/month

Three wavelength Infrared Gas Detector , Open Path Flammable Gas Detector

Description
Name: HiYi Atex HONEYWELL Three Infrared Sensor Short Range 30m – 40m 4-5um Infrared Open Path Flammable Gas Detector Response Spectral Range: 4-5um
Viewing Angle Range: 90 ° Detection Distance: 30--50 Meter (depends On The Burning Material)
Explosion-proof Grade: EXdⅡCT6 Protection Grade: IP66
Size: 19*16*11 Cm Weight: 1.7 Kg
High Light:

30m Flammable Gas Detector

,

40m Infrared Gas Detector

,

Open Path Flammable Gas Detector

HiYi Atex HONEYWELL Three Infrared Sensor Short Range 30m – 40m 4-5um Infrared Open Path Flammable Gas Detector
MIC200-IR3 Three-wavelength Point-type
Infrared Flammable Gas Detector| Three-wavelength | 30--50M
 
OVERVIEW

 

The MIC200 Three-band Infrared Flame Detector is Sight Gas detection System is a proven open path gas detection solution which aids in high speed detection of flammable gases such as Methane, Ethane, Propane, Butane, Pentane, Ethylene, Propylene, Butadiene in Short range (5 to 40m) distances comes with approved certification for ATEX.

It's a reliable and high-performance flame detector. It uses advanced flame analysis and identification technology to quickly respond to infrared radiation in a fire and has the highest false alarm immunity .
The MIC-200-IR3 detector contains three narrow-band infrared sensors (4-6 microns) and optical filters, which have high sensitivity to carbon dioxide emission spectra (4.4 microns), which can effectively eliminate interference and achieve detection for a much longer distance.
The special fire signal processing method and multi-sensor detection technology greatly improve the sensitivity and response time of the detector. The detector is suitable for liquid and gas fires, open flames with smoke and places where deflagration occurs.


Three wavelength Infrared Gas Detector , Open Path Flammable Gas Detector 0

SPECIFICATION

 

Response spectral range
 4-5um
Response time
 5--10s The response time of different media is different
Viewing angle range
 90 °
Detection distance
 30--50 meter (depends on the burning material)
Ambient temperature
 -10 ~ 55 ℃
Environmental humidity
 ≤95% RH
Pressure range
 86 ~ 106Kpa
Working voltage
 DC24V
Working current
 current≤25mA, alarm current≤35mA
Executive standard
 GB15631-2008, GB3836- 2000 series
Explosion-proof grade
 EXdⅡCT6
Protection grade
 IP66
Signal output
 4~20mA three-wire system output
Installation method
 wall or ceiling
Cable outlet thread
 20mmX1.5mm free conversion G1 / 2 optional
Dimensions 
 19*16*11 cm
Shell material
 aluminum alloy, surface anticorrosive paint sprayed
Weight
 1.7 Kg
Advantages
 dustproof, explosion-proof, corrosion-proof

 

FEATURES & BENEFITS

 

  • Developed by the principle of three- wavelength infrared detection, it has high immunity to false alarms;
  • High-speed response to flame;
  • Built-in high-performance microprocessor;
  • Excellent anti-radio frequency and electromagnetic interference performance;
  • Reliable system fault self-diagnosis function;
  • Two output modes of three-wire current loop and relay are optional;
  • Patented signal processing algorithm to minimize the possibility of false alarms;
  • Multi-level sensitivity settings to meet the different needs of more occasions;
  • Easy to install, the detection angle can be adjusted by 360° ;
  • ExdII CT6 explosion-proof grade, suitable for zone 1 and zone 2 hazardous locations.

Three wavelength Infrared Gas Detector , Open Path Flammable Gas Detector 1Three wavelength Infrared Gas Detector , Open Path Flammable Gas Detector 2

 

APPLICATION

 

• Offshore platforms & vessels (FPSO’s)

• Downstream chemical processing plants
• Gas transport and pipelines
• Large storage areas & buildings
• Perimeter detection

 

Three wavelength Infrared Gas Detector , Open Path Flammable Gas Detector 3

Contact Details
Beijing HiYi Technology Co., Ltd

Contact Person: Lisa Niu

Tel: 86-15699785629

Fax: +86-010-5653-8958

Send your inquiry directly to us (0 / 3000)