|
Product Details:
|
| Highlight: | Portable ATEX gas detector,Ethylene Oxide gas detector 1500ppm,Addressable fire alarm panel |
||
|---|---|---|---|
The PTM100 Portable VOC Analyzer is a professional field instrument designed for measuring volatile organic compounds (VOCs) in industrial and environmental applications. Combining flame ionization detection (FID) with an optional photoionization detector (PID), the analyzer provides flexible VOC measurement capabilities for different inspection requirements.
The standard FID measurement system covers concentrations from 0 to 100,000 ppm, while the optional PID channel offers a range of 0 to 2,000 ppm. When equipped with both detectors, the instrument supports simultaneous FID and PID operation.
The PTM100 features a fast-response gas sampling system with an adjustable flow rate of 800 mL/min. Its response time is specified at T90 ≤3.5 seconds under the stated reference gas test conditions, supporting rapid investigation of changing VOC concentrations.
For field operation, the instrument provides automatic FID ignition and continuous flame temperature monitoring. A digital hydrogen pressure display and estimated hydrogen operating time help users manage instrument operation.
A separate 6.5-inch touchscreen handheld controller supports Bluetooth and Wi-Fi communication, providing an interface for instrument operation and measurement review.
With a rechargeable power system and specified battery operation of at least 10 hours at 0°C, the PTM100 is suitable for extended VOC inspection activities.
Portable VOC measurement using flame ionization detection.
Standard FID and optional PID sensing technologies.
Simultaneous FID/PID operation when both detectors are installed.
FID measuring range of 0–100,000 ppm.
Optional PID measuring range of 0–2,000 ppm.
FID method detection limit of 0.5 ppm methane.
PID method detection limit of 0.5 ppm isobutylene.
Fast T90 response time of ≤3.5 seconds under specified test conditions.
Adjustable 800 mL/min sampling flow.
Automatic FID flame ignition.
Continuous flame temperature supervision.
Digital hydrogen pressure indication.
Estimated remaining hydrogen operating time.
Real-time battery status and operating-time indication.
Integrated VOC reference library covering more than 200 compounds.
6.5-inch touchscreen handheld controller.
Bluetooth and Wi-Fi communication through the controller.
Explosion-protected main instrument design.
Rechargeable battery with ≥10 hours of operation at 0°C.
Hydrogen supply endurance of ≥15 hours.
Leak Detection and Repair (LDAR)
Industrial VOC leak investigations
Oil and gas production facilities
Gas gathering and processing systems
Storage tank and equipment inspections
VOC screening above liquid surfaces
Rapid soil vapor screening
Environmental site investigations
Regional VOC surveys
Industrial environmental monitoring
| Parameter | Specification |
|---|---|
| Model | PTM100 |
| Product Type | Portable VOC Analyzer |
| Standard Detector | Flame Ionization Detector (FID) |
| Optional Detector | Photoionization Detector (PID) |
| Dual-Detector Operation | Simultaneous FID and PID operation when equipped |
| FID Measurement Range | 0–100,000 ppm |
| PID Measurement Range | 0–2,000 ppm; optional configurations |
| FID Method Detection Limit | 0.5 ppm methane |
| PID Method Detection Limit | 0.5 ppm isobutylene |
| Measurement Accuracy | ±5% of reading or ±1 ppm, whichever is greater |
| FID Repeatability | 2% at 500 ppm methane |
| PID Repeatability | 1% at 100 ppm isobutylene |
| FID Response Time | T90 ≤3.5 s at 10,000 ppm methane |
| PID Response Time | T90 ≤3.5 s at 500 ppm isobutylene |
| Sampling Flow Rate | 800 mL/min, adjustable |
| FID Ignition | Fully automatic |
| Flame Monitoring | Continuous flame temperature supervision |
| Hydrogen Pressure | Digital indication |
| Hydrogen Runtime Estimation | Supported |
| VOC Library | More than 200 compounds |
| Handheld Controller | 6.5-inch touchscreen |
| Controller Communication | Bluetooth and Wi-Fi |
| Main Unit Explosion Protection | Ex db ia IIC T4 Gb, source-stated marking |
| Handheld Controller Protection | Ex ib IIC T4 Gb / Ex ibD 21 T130°C, source-stated marking |
| Battery Operating Time | ≥10 h at 0°C |
| Hydrogen Endurance | ≥15 h |
| Power Adapter | DC 8.4 V, 1 A |
| Operating Temperature | -30°C to +45°C |
| Operating Humidity | 10–95% RH |
| Gas Connection | 1/4 inch |
| Main Unit Weight | 3.5 kg |
The FID system measures the response of suitable organic compounds in a hydrogen flame. It provides a wide concentration measurement range for industrial VOC monitoring.
The optional PID sensor provides an additional measurement channel for compounds detectable by photoionization.
When both detectors are installed, the system can operate the FID and PID channels simultaneously.
The PTM100 combines high-range FID measurement, optional PID detection, fast sampling and intelligent field operation in one portable VOC analysis platform.
Its measurement capabilities make it suitable for industrial leak detection, environmental screening and applications requiring rapid assessment of volatile organic compound concentrations.
Contact Person: Lisa Niu
Tel: 86-15699785629
Fax: +86-010-5653-8958