Product Details:
|
Name: | HiYi Internal Pump High Accuracy Buzzer Oxygen O2 Gas Leakage Personal Single Gas Detector | Test Range: | 0-30%VOL |
---|---|---|---|
Certificate: | CE/FCC/ATEX | Response Time: | T90<30s |
Alarm: | Sound+Light Alarm | Power Supply: | Lithium Battery |
Work Time: | 12 Hours | Dimensions: | 228* 84 * 50.5mm |
Weight: | 0.55 Kg | ||
High Light: | ATEX Single Gas Detector,Internal Pump Single Gas Detector,High Accuracy Leakage Gas Detector |
Portable Gas Detector
O2 Oxygen
Accurate oxygen (O2) level measurements are essential in preventing injury or death in situations where safe levels may be compromised. Oxygen gas detection instruments will typically trigger an alarm when the oxygen level drops below 19.5% volume, the OSHA-mandated level.
The most common use of oxygen gas detection is in confined spaces – totally or partially closed areas generally not designed to be permanently occupied. It is essential that an O2 gas sample is drawn prior to entering these spaces, and is continuously monitored after entry.
HiYi Technology offers single-gas detector or multi-gas detectors, workers can monitor exposure in areas where gases may be present. In areas where workers could be exposed to additional gases, the gas detector will keep workers safe.
XM-E Portable Gas Detector is a continuous monitoring of a variety of single gas detection equipment.
This product is suitable for environmental monitoring, industrial production and other harmful gases working environment, which can effectively protect the health and safety of staff is not compromised.It meets European standard gas detector.
Sampling way
|
Pump priming
|
Resolution
|
according to the range
|
Precision
|
±5%FS
|
Response time
|
T90<30s
|
Indicate way
|
LCD display real-time concentration ,LED ,buzzer alarm
|
Data storage
|
Can store multiple sets of data
|
Pressure range
|
Atmospheric pressure
|
Power supply
|
Lithium battery (3.7V/3000Ah)
|
Operating Current
|
normal current:≤ 150mA; Alarm current: ≤ 200mA
|
Operating Temperature
|
-40 ℃ - 70 ℃
|
Relative Humidity
|
15% - 95%, non-condensing
|
Storage Temperature
|
-20 ℃ - 60 ℃
|
Storage humidity
|
≤ 90%, no condensation
|
Continuous work hours
|
12hours
|
Charge time
|
6-8hours
|
Dimensions
|
228* 84 * 50.5mm
|
Installation
|
Handheld / Stand-in
|
Weight
|
0.55 kg
|
Protection Class
|
IP65
|