Product Details:
Place of Origin: China
Brand Name: HiYi
Certification: CE/RoHS
Model Number: XM-E-CL2
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD 200-800/pcs
Packaging Details: alloy case
Delivery Time: 3-7 days
Payment Terms: L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram
Supply Ability: 10000 set/month

2000ppm Chlorine CL2 Gas Detector Buzzer Alarm Pump Priming

Description
Name: Portable CL2 Gas Detector Sampling: Internal Pump
Test Range: 0-20/200/2000ppm Material: ABS+PC
Sensor: Membrapor Sensor(optional) Response Time: T90<30s
Alarm: Sound+Light Alarm Power Supply: Lithium Battery (3.7V/3000Ah)
Operating Temperature: -40 ℃ - 70 ℃ Relative Humidity: 15% - 95%, Non-condensing
High Light:

2000ppm Chlorine Gas Detector

,

Chlorine CL2 Gas Detector

,

Buzzer Alarm CL2 Gas Detector

 

Portable  Gas Detector

CL2 Chlorine

 

ABOUT CHLORINE GAS DETECTORS (CL2 DETECTORS)

 

Chlorine is greenish yellow gas with a characteristic pungent odor. Although not classified as an explosive gas, chlorine will react explosively or form an explosive compound when combined with substances like acetylene, ether, turpentine, ammonia, hydrogen, and fuel gas.

 

Chlorine derivatives are commonly used for their disinfectant properties. Chlorine is highly toxic. The toxins take their route through the lungs irritating the respiratory tract. High doses of chlorine gas can cause death quite rapidly.

 

Chlorine (Cl2) is found in many industrial processes, including those used to make plastics and in the manufacturing of agricultural pesticides. It is used by pharmaceutical, food and beverage, pulp and paper, and electronics industries, as well as wastewater treatment facilities. Chlorine is also used in the manufacturing of gasoline additives, brake fluid, and antifreeze. Oil refineries inject chlorine directly into stacks to reduce sulfur emissions. Proper chlorine gas detection is essential in areas where workers are most likely to be exposed to toxic Cl2 gas, such as storage tank areas and near processing units.

 

HiYi Technology offers single-gas detector or multi-gas detectors, reliably detect within the specified range.

 

OVERVIEW

 

XM-E Portable Gas Detector is a continuous monitoring of a variety of single gas detection equipment.

This product is suitable for environmental monitoring, industrial production and other harmful gases working environment, which can effectively protect the health and safety of staff is not compromised.It meets European standard gas detector.

 

2000ppm Chlorine CL2 Gas Detector Buzzer Alarm Pump Priming 0

 

SPECIFICATION

 

Sampling way
Pump priming
Test range optional
Resolution
according to the range
Indicator LCD display
Precision
±5%FS
Response time T90<30s
Data storage Can store multiple sets of data Pressure range Atmospheric pressure

Battery

 
Lithium battery
Power 3.7V/3000 mAh
normal current ≤ 150mA Alarm current ≤ 200mA
Operating Temperature
-40 ℃ - 70 ℃
Relative Humidity 15% - 95%, non-condensing
Storage Temperature -20 ℃ - 60 ℃ Storage Humidity ≤ 90%, no condensation
Sensor life 1 year Work Hours 12hours
Charge time 6-8hours Installation Handheld / Stand-in
Dimensions
228* 84 * 50.5mm
Weight 0.55 Kg

 

FEATURES & BENEFITS 

 

  • Intelligent Probe design;convenient calibration and maintenance
  • Fault, Warning, operator error, alarm will be smart tips
  • Built-in CF calibration coefficients (VOC measurements only valid)
  • With audible alarm, visual alarm function, the status bar also displays alarm status
  • Full-color 3.5-inch TFT screen, color LCD display and intuitive
  • Can be both digital and curve display of gas concentration in two ways
  • With USB communication port, you can speed 9600 bytes to communicate directly with the computer
  • With test record function, can store a month's measurement data and instrument or computer can view the data
  • Memory capacity is 2M,can store more than 90,000 pieces of data
  • With alarm recording function, you can record the last four times the alarm time and type
  • With calibration record; can record the last four times the size of the calibration time span
  • High-capacity lithium battery-powered, rechargeable, low battery automatic shutdown
  • Can be set high reported, underreporting, TWA, STEL, shutdown time, pump speed, etc.
  • Indicate way : LCD display real-time concentration ,LED ,buzzer alarm 

2000ppm Chlorine CL2 Gas Detector Buzzer Alarm Pump Priming 1

APPLICATION 

 

The detector is widely used in municipal pools, pulp and paper, waste water treatments plants, Hazmat teams,
railroad yards.

 

The detector can effectively predict the concentration of dangerous gas alarm, to ensure that the safety of staff life is not threatened, production equipment is not lost.

 