Home ProductsSingle Gas Detector

MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online

Customer Reviews
High quality machine, it works wonderful and quiet. very good service.

—— Nor

Excellent Product, popular in the team.

—— Fernando

I'm Online Chat Now

MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online

MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online
MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online

Large Image :  MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online

Product Details:
Place of Origin: China
Brand Name: HiYi
Certification: CE
Model Number: MIC500S-CO
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: paper case
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online

Description
Product Name: Carbon Monoxide Fixed CO Gas Monitor Type: Fixed Gas Detector
Gas: CO Gas Weight: 1.8(kg)
Size: 210*170*85mm (L*H*W) Gas Unit: PPM, Mg/m3, Vol%, LEL%, PPHM, Ppb, Mg/l
High Light:

emi carbon monoxide gas detector

,

explosion proof carbon monoxide gas detector

,

emi carbon monoxide and gas detector

MIC500S-CO Fixed Carbon Monoxide Online Gas Detector

 

1. It is compliant with EMI, and EMC standards.

2. Multiple alarm modes, and multi-directional and three-dimensional indication alarm states.

3. Zero-point automatic tracking; long-term use will not be affected by the zero drift.

4. Intrinsically safe circuit design, explosion-proof, with Level II lightning protection, and anti-static capabilities.

Meet the national standard, and it is resistant to the high-intensity pulse surge current. With the function of preventing the reverse connection.

5. Diversified communication methods

·It is possible for the real-time monitoring via the wired or remote wireless transmission, and network transmission; three-wire system 4 ~ 20mA standard signal and standard bus RS485 (modbus-RTU) simultaneous output;

·It is possible to select frequency output 200-1000Hz, Hart protocol signal, 1 ~ 5V output, two-wire system 4 ~ 20mA, SMS alarm, wireless transmission (2 ~5 km or unlimited distance);

·It is compatible with secondary instrument, data acquisition module, PLC, DCS system, and it is possible to drive the

related equipment.

 

OVERVIEW

 

MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online 0
MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online 1
 

 

FEATURES & BENEFITS

 

MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online 2

 

MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online 3

 

MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online 4

 

MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online 5

 

SPECIFICATION

 

Gases to be detected Toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.
Application scenarios All the cases which requires the fixed installation, and online detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
Resolution 0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm),
0.1ppm (0 ~ 1000 ppm),
1ppm (0 ~ 10000 ppm or more),
0.01 mg/l (0 ~ 200 mg/l),
0.1% LEL,
0.01%,
0.001% Vol
Detection principle Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor service life Electrochemical principle: 2 ~ 3 years;
Oxygen gas: 2 years or 6 years can be selected;
Infrared principle: 5 ~ 10 years;
Catalytic combustion: 3 years;
Thermal conductivity: 5 years.
Allowable error ≤±3% F.S (other or higher precision levels can be customized)
Linearity ≤±2% Repeatability ≤±2% Uncertainty ≤±2%
Response time T90≤20 seconds Recovery time ≤30 seconds
Signal output Bus system RS485 (RTU), three (four) wire system 4 ~ 20mA, optional configuration: 0 ~ 20mA, 1 ~ 5V, 0 ~ 5V, 0 ~ 10V, wireless
transmission, network transmission, and SMS alarms.
Working environment Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH (regular) non-condensing case .
It should be customized in the case of use in the condensing case, or the use environment should be specified at the time of ordering.
Display method 1.7-inch high-definition color screen for field display, it is possible to select no field display, or the optional configuration of MIC2000 controller for remote display, control, and alarm.
Working voltage 12 ~ 30VDC direct current, the standard power supply for a single equipment is 24V, DC stabilized voltage switching power supply of 1A or greater than 1A.
Power supply reference The switching power supply of 24V, 2.1A is possible to drive 40 units of toxic gas detector, or 15 units of flammable, infrared gas detector.
Working method Fixed type installation, online detection, diffusion type measurement; and it is possible to select the measurement of pipeline type, flow-through type, and pump-suction type.
Installation method Pipeline type, and wall mounting type. The working pressure of the pipeline type is ± 30% of atmospheric pressure, and when exceeded this range, it is necessary for the depressurization treatment.
Alarm mode The default option is 1-way, and it is possible to select 2-way passive contact (dry contact) output, level III alarm, and the alarm point can be set. Field sound & light alarm (optional configuration).
Communication interface Adopted 4 ~ 20mA three-core shielding cable, adopted four-core for RS485, when the distance exceeded 100 meters, the single wire diameter ≥1.5mm; and the shielding layer will be connected to the earth.
Protection level IP65
Explosion-proof type Explosion suppression type
Explosion-proof mark ExdⅡCT6, certificate number: CNEx15.1283
Exterior dimensions 210×170×85mm (L×H×W)
Weight 1.8Kg
Standard accessories Manual, qualification certificate, warranty card, outer packaging box
Optional items Integrated sound & light alarming device, split-type sound & light alarming device, 24V DC stabilized voltage power supply, accessory for connection with computer for monitoring: free upper-level host software, RS485 / RS232 converter.
For laptop without RS232 interface, USB / RS232 converting and connecting cable is needed, if the network transmission is needed, TCP / IP converter will be further needed.
Wireless transmission Optional function is possible to transfer data wirelessly to the cell phone, remote monitoring center, monitoring computers and other monitoring equipment, which will utilize the upper-level host to realize the functions of data analysis, storage, printing or the like on the computer
Pretreatment system Optional configuration: room temperature and high humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature and high humidity and high dust pretreatment system
Installation type accessories Optional configuration: wall mounting bracket, mounting clips for fixation on the pipes (1/2", 3/4" pipe),
stainless steel threaded welding seat or flange to be installed on the pipeline (it is necessary to mark the flange or pipe size, such as DN50, DN15 ...),
rain cover, 24VDC or 220AC sampling pump (sampling distance is 10 m), vacuum pump (sampling distance is greater than 40 m),
24V switching power supply, pressure reducing valve, flow meters.

 

APPLICATION  

 

 

MIC500S-CO Fixed EMI Carbon Monoxide Gas Detector Online 6

Contact Details
Beijing HiYi Technology Co., Ltd

Contact Person: Lisa Niu

Tel: 86-15699785629

Send your inquiry directly to us (0 / 3000)